USEPA Method 7 (Add-on) Set
Meets or exceeds the following methods/laws/requirements:
US EPA Method 7:
Section 6.1 (Sample Collection) but excluding:
- Section 6.1.9 (Volumetric Pipette)
- Section 6.1.10 (Stopcock and Ground Joint Grease)
- Section 6.1.11 (Barometer)
Product Description
Start your grab sampling (non-isokinetic smoke-stack testing) using US EPA Method 7 (Nitrogen Oxide, NOx) upon unpacking. This sampling method is used to measure nitrogen oxides (NOx except Nitrous Oxide, N2O) in the flue gas emitted by stationary sources of air pollution.
Sample gas is collected in an evacuated flask containing a dilute sulfuric acid-hydrogen peroxide absorbing solution, and the nitrogen oxides, except nitrous oxide, are measured colorimetrically using the phenoldisulfonic acid (PDS) procedure.
Requires some items from the USEPA Method 5 Basic Set to function.
N.A.
Product Specifications
OD of Heated Sampling Line (flexible probe):
Teflon tubing Only: 1/4 inch (6.35 mm)
Teflon tubing With the heater and insulation tubing: ~1.18-1.57 inch (~30-40 mm)
Other Information
Absorbing solutions/chemicals are NOT included.
Consider buying additional glassware in case of accidental breakage during sampling.
Consider buying transport cases if you will be travelling too far from your main offices.
All our products come with a one-year warranty against manufacturing defects and one-month technical support for free. Please refer to our Frequently Asked Questions (FAQs) page for more details.
-----
Information presented here is subjected to Aer Sampling Group's terms and conditions.
In case of discrepancy between English version and the non-English version, the English version shall prevail.
Doc ID: AERHQWW-s-42-en
Last revised (Excluding prices): 0^; 06.08.21
Obsolete Catalog ID: US-M7
-----
Bill of Materials (BOM)
What does this product contain? (r4):
The following items are included. Click the Catalog ID below to view individual components of this product.
S/N | Catalog ID | Quantity | Product Name |
1 | PN-719 | x1 |
USEPA Method 7 Valve Assembly [EACH]
|
2 | PN-748 | x1 | 6 inch Straight Thermocouple [EACH] |
3 | PN-967 | x1 | Handy Power Box Assembly with Support [EACH] |
4 | PN-1234 | x1 | 220-240V, 8 ft, USEPA Method 7 Heated Sampling Line [EACH] |
5 | PN-1236 | x1 | USEPA Method 7 Probe Clamp Assembly [EACH] |
6 | K-160 | x1 | USEPA Method 7 Flask Kit [EACH] |
What does this product need to work? (r4):
Items not included in this set/kit but are needed to make this set/kit works. We assume you already have the items below
S/N | Catalog ID | Quantity | Item Name |
1 | PN-357 | x1 | Leak-free Stack Testing Pump Assembly, 220-240V [EACH] |
2 | PN-380 | x1 | Impinger Box Assembly, Large [EACH] |
3 | PN-1271 | x1 | Umbilical Cable Assembly, 100', w/o Orsat Line [EACH] |
4 | PN-1273 | x1 |
MREK 504 Metering Console Assembly w/o case, |