S-21 USEPA method 29 sampling train schematic a1

USEPA Method 29 (Add-on) Set --- S-21

  • $1,015.00


Meets or exceeds the following methods/laws/requirements:

US EPA Method 29:

Section 6.1.5 (Condenser) but excluding chemicals (silica gel, nitric acid/hydrogen peroxide, etc.)
Section 6.1.7 (Teflon tape)
Section 6.2.1 (Non-metallic Probe-Liner and Probe-Nozzle Brushes or Swabs)
Section 6.2.2 (Sample Storage Containers)
Section 6.2.4 (Funnel)
Section 6.2.6 (Polypropylene Tweezers)
Section 7.2.1 (Sample Filters)


Product Description

Start isokinetic sampling (smoke-stack testing) using US EPA Method 29 (Metal Emissions) upon unpacking. This sampling method is used to measure the following list of metals, containing in the flue gas emitted by stationary sources of air pollution.

Metal elements:

Antimony (Sb), Arsenic (As), Barium (Ba), Beryllium (Be), Cadmium (Cd), Chromium (Cr), Cobalt (Co), Copper (Cu), Lead (Pb), Manganese (Mn), Mercury (Hg), Nickel (Ni), Phosphorus (P), Selenium (Se), Silver (Ag), Thallium (Tl), Zinc (Zn)

This set uses Aer Sampling’s Standard Configuration where the full-length heating box—MKORTM Heater Box (Hot Box), the Box Extender (Riser Box) and the Impinger Box (Cold Box) is hung onto a monorail and move in or out the porthole of the chimney/stack, while traversing the smoke-stack.

Requires the USEPA Method 5 Basic Set—which uses Aer Sampling’s Standard Configuration, to use this add-on set.

Other Applicable Documents:
N.A.


Product Specifications

Minimum porthole inside diameter needed: ~4 in. (10 cm) 

-----
Click on the links in the BOM tables below to view the specifications of individual components of this product.


Other Information

Chemicals are NOT included.

Consider buying additional glassware in case of accidental breakage during sampling.
Consider buying transport cases if you will be travelling too far from your main offices.

All our products come with a one-year warranty against manufacturing defects and one-month technical support for free. Please refer to our Frequently Asked Questions (FAQs) page for more details.



-----

Information presented here is subjected to Aer Sampling Group's terms and conditions. 
In case of discrepancy between English version and the non-English version, the English version shall prevail.
Doc ID: AERHQWW-s-21-en
Last revised (Excluding prices): 0; 06.08.21
Obsolete Catalog ID: US-M29

 

-----

Bill of Materials (BOM)

What does this product contain? (r4):

The following items are included. Click the Catalog ID below to view individual components of this product.

S/N Catalog ID Quantity Item Name
1
PN-493
x3 Impinger Bottle, 500ml  [EACH]
2
K-173
x2 Plain Impinger Insert Kit  [EACH]
3
K-172
x1 Short Impinger Insert Kit  [EACH]
4
PN-605
x3 Impinger Connector  [EACH]
5
PN-342
x6 Ball Joint Clamp S28  [EACH]
6
PN-405
x1 Nozzle Brush, PTFE  [EACH]
7
PN-417
x1 Tweezer, PP  [EACH]
8
PN-413
x1 Funnel, Glass  [EACH]
9
PN-397
x1 Quartz Filters, Round, 82mm  [EACH]
10
PN-416
x1 Tape, PTFE  [EACH]
11
PN-387
x2 Bottle, Glass, Wide Mouth, PTFE Cover, 1 Liter  [EACH]
12
PN-919
x1 Union, straight, 16mm, body, PTFE  [EACH]
13
PN-918
x1 Nut, 16mm PTFE  [EACH]

 

What does this product need to work? (r4):

Items not included in this set/kit but are needed to make this set/kit works. We assume you already have the items below. 

S/N Catalog ID Quantity Item Name
1 S-28
S-48
1x USEPA Method 5 Basic Set  [EACH]

We Also Recommend