USEPA Method 29 (Add-on) Set --- S-21
Meets or exceeds the following methods/laws/requirements:
US EPA Method 29:
Section 6.1.5 (Condenser) but excluding chemicals (silica gel, nitric acid/hydrogen peroxide, etc.)
Section 6.1.7 (Teflon tape)
Section 6.2.1 (Non-metallic Probe-Liner and Probe-Nozzle Brushes or Swabs)
Section 6.2.2 (Sample Storage Containers)
Section 6.2.4 (Funnel)
Section 6.2.6 (Polypropylene Tweezers)
Section 7.2.1 (Sample Filters)
Product Description
Start isokinetic sampling (smoke-stack testing) using US EPA Method 29 (Metal Emissions) upon unpacking. This sampling method is used to measure the following list of metals, containing in the flue gas emitted by stationary sources of air pollution.
Metal elements:
Antimony (Sb), Arsenic (As), Barium (Ba), Beryllium (Be), Cadmium (Cd), Chromium (Cr), Cobalt (Co), Copper (Cu), Lead (Pb), Manganese (Mn), Mercury (Hg), Nickel (Ni), Phosphorus (P), Selenium (Se), Silver (Ag), Thallium (Tl), Zinc (Zn)
This set uses Aer Sampling’s Standard Configuration where the full-length heating box—MKORTM Heater Box (Hot Box), the Box Extender (Riser Box) and the Impinger Box (Cold Box) is hung onto a monorail and move in or out the porthole of the chimney/stack, while traversing the smoke-stack.
Requires the USEPA Method 5 Basic Set—which uses Aer Sampling’s Standard Configuration, to use this add-on set.
N.A.
Product Specifications
Minimum porthole inside diameter needed: ~4 in. (10 cm)
-----
Click on the links in the BOM tables below to view the specifications of individual components of this product.
Other Information
Chemicals are NOT included.
Consider buying additional glassware in case of accidental breakage during sampling.
Consider buying transport cases if you will be travelling too far from your main offices.
All our products come with a one-year warranty against manufacturing defects and one-month technical support for free. Please refer to our Frequently Asked Questions (FAQs) page for more details.
-----
Information presented here is subjected to Aer Sampling Group's terms and conditions.
In case of discrepancy between English version and the non-English version, the English version shall prevail.
Doc ID: AERHQWW-s-21-en
Last revised (Excluding prices): 0; 06.08.21
Obsolete Catalog ID: US-M29
-----
Bill of Materials (BOM)
What does this product contain? (r4):
The following items are included. Click the Catalog ID below to view individual components of this product.
S/N | Catalog ID | Quantity | Item Name |
1 | PN-493 | x3 | Impinger Bottle, 500ml [EACH] |
2 | K-173 | x2 | Plain Impinger Insert Kit [EACH] |
3 | K-172 | x1 | Short Impinger Insert Kit [EACH] |
4 | PN-605 | x3 | Impinger Connector [EACH] |
5 | PN-342 | x6 | Ball Joint Clamp S28 [EACH] |
6 | PN-405 | x1 | Nozzle Brush, PTFE [EACH] |
7 | PN-417 | x1 | Tweezer, PP [EACH] |
8 | PN-413 | x1 | Funnel, Glass [EACH] |
9 | PN-397 | x1 | Quartz Filters, Round, 82mm [EACH] |
10 | PN-416 | x1 | Tape, PTFE [EACH] |
11 | PN-387 | x2 | Bottle, Glass, Wide Mouth, PTFE Cover, 1 Liter [EACH] |
12 | PN-919 | x1 | Union, straight, 16mm, body, PTFE [EACH] |
13 | PN-918 | x1 | Nut, 16mm PTFE [EACH] |
What does this product need to work? (r4):
Items not included in this set/kit but are needed to make this set/kit works. We assume you already have the items below.
S/N | Catalog ID | Quantity | Item Name |
1 |
S-28 S-48 |
1x | USEPA Method 5 Basic Set
[EACH] |