English  Español  ภาษาไทย  Bahasa Indonesia 
S-24 USEPA method 17 sampling train schematic a1

USEPA Method 17 (Add-on) Set --- S-24

  • $1,538.00


Meets or exceeds the following methods/laws/requirements:

US EPA Method 17:

Section 6.1 (Sampling Train) but excluding gas density determination equipment
Section 7.1 (Sampling) but excluding chemicals (silica gel, water, crushed ice, and stopcock grease)
Section 8.1.2 (Preliminary Determinations)


Product Description

Start in-stack isokinetic sampling (smoke-stack testing) using US EPA Method 17 (Particulate Matter or Dust) upon unpacking. This sampling method collects particulate matter from a flue gas emitted by stationary sources of air pollution. Collection of particulate matter occurs inside the stack (in-stack) and at the stack temperature. Thus, a heated glass probe and a heated filtering system are no longer required.

The Impinger Box (Cold Box) is placed on the ground or a smoke-stack platform, separately from the part of the sampling train that is traversing the smoke-stack. No longer need to move this Cold Box when moving in and out of the sampling porthole—which is usually the case in Aer Sampling’s Standard Configuration.

Requires the USEPA Method 5 Basic Set to use this add-on set.

Other Applicable Documents:
N.A.


Product Specifications

Minimum porthole inside diameter needed: ~4.7 in. (12 cm)

-----
Click on the links in the BOM tables below to view the specifications of individual components of this product.


Other Information

All our products come with a one-year warranty against manufacturing defects and one-month technical support for free. Please refer to our Frequently Asked Questions (FAQs) page for more details.



-----

Information presented here is subjected to Aer Sampling Group's terms and conditions. 
In case of discrepancy between English version and the non-English version, the English version shall prevail.
Doc ID: AERHQWW-s-24-en
Last revised (Excluding prices): 0; 11.23.20
Obsolete Catalog ID: US-M17

 

-----

Bill of Materials (BOM)

What does this product contain? (r2):

The following items are included. Click the Catalog ID below to view individual components of this product.

S/N Catalog ID Quantity Item Name
1 PN-946 x1 SUS In-stack Thimble Filter Holder Assembly [EACH]
2 K-205
x1 Pitot Tube Tip Replacement Kit [EACH]
3 PN-1111
X1 25x90 mm Thimble Glass Fiber Filters, 25pc/box [EACH]
4 PN-1389 x1 S-type Extended 302 Offset Pitot Tube Tip Assembly [EACH]
5 PN-1394 x1 O-ring, Silicon Rubber 394 [EACH]
6 PN-331 x1 Handy Power Box Assembly [EACH]
7 PN-333
x1
Strain Relief Assembly, In-stack Filter [EACH]
8 PN-335
x1 10 ft Unheated Sampling Line, Handy [EACH]
9 PN-371
x1 6 ft SUS Probe Liner (Type B) Assembly [EACH]
10 PN-383
x1
Strain Relief Assembly, Impinger Inlet [EACH]

 

What does this product need to work? (r2):

Items not included in this set/kit but are needed to make this set/kit works. We assume you already have the items below 

S/N Catalog ID Quantity Item Name
1 S-28